Explosion-proof IP68 Actuator Multi-turn BD300-IIC

  • Power supply: three-phase: 380Vac±10% 50Hz±2%; single phase: 220Vac±10% 50Hz±2%
  • Input signal: DC4-20mA; dry contact; DC24V and AC220V pulse and electric frequency signals
  • Output signal: DC4-20mA; 4 groups of bistable output contacts configurable in the field, 1 group of monostable output contacts for remote instruction, and 1 group of monostable output contacts of fault alarm.
  • Output contact capacity: 250Vac/5A or 30Vdc/5A
  • Output current load impedance: ≤750Ω
  • Ambient temperature: -30°C- +70°C
  • Protection class: IP68
  • Flange standard: ISO 5210:2017 (GB/T12222-2023)
  • Explosion-proof marking: Ex db IIC T4 Gb; Ex tb IIIC T130℃ Db 
  • Approvals (optional): ATEX, IECEx, CSA (available on request with longer lead time).

Description

Explosion-proof IP68 Actuator Overview

Engineers specify the explosion-proof IP68 actuator multi-turn BD300-IIC series when they need absolute reliability in hazardous areas. Bonray — an ISO 9001-certified factory with deep expertise in explosion-proof equipment — manufactures this explosion-proof IP68 actuator multi-turn to withstand gas explosions (Ex db IIC T4 Gb) and dust explosions (Ex tb IIIC T130°C Db). The explosion-proof IP68 actuator multi-turn  uses a non-contact absolute encoder (BM18 patent) that stores valve position without batteries, while the dual-seal IP68 housing allows submersion. Whether you control a penstock in a flood barrier or a choke valve in a refinery, this multi-turn intelligent actuator provides real-time torque readout, configurable ESD, and multiple fieldbus options. The factory backs every unit with a 48-hour submerged test before shipping.

Field Application of BDBDM-IIC Explosion-proof IP68 Actuator
Field Application of BDBDM-IIC Intelligent

Does the factory offer a version that keeps output contacts latched during a power failure?

Yes. The standard S1-S4 contacts are bistable. They maintain their position even when you completely disconnect power from the explosion-proof IP68 actuator multi-turn . This is critical for valve position indication in solar-powered or remote telemetry systems.

Explosion-proof IP68 Actuator Features

  1. Dual-Cable Entry Redundancy: The terminal box includes three entries (M27x2 + 2x M20x1.5 for small frames; M32x1.5 + 2x M20x1.5 for large frames). You can route power separately from signal cables, reducing EMI on the explosion-proof IP68 actuator multi-turn.

    Dual-sealed structure of Explosion-proof IP68 Actuator
    Dual-sealed structure

    Fieldbus Cards
    Fieldbus Cards
  2. Remote Forced Local Bypass: The “Remote” indication contact (terminals 15-16) tells your DCS when the multi-turn intelligent actuator is in local mode. You cannot accidentally leave the actuator in local after maintenance — the system will alarm.

  3. Thermal Reconnection Hysteresis: The motor thermostat auto-resets after cooling. This prevents nuisance lockouts. The explosion-proof IP68 actuator multi-turn  will resume operation once the winding temperature drops below the threshold.

  4. Magnetic Limit Setting: You set the open and close limits by rotating the knob without any tools. The Hall sensor detects the magnet position inside the sealed multi-turn intelligent actuator housing, ensuring no ingress points.

  5. Torque Profile Recording: The multi-turn intelligent actuator stores peak torque values during stroke. You can retrieve this data to diagnose valve packing wear or seat galling.

  6. Selectable Fail Direction: Using the menu, you decide the multi-turn intelligent actuator’s behavior on loss of control power: stay put, move to close, or move to open.

Model and Type

The BD300-IIC on-off actuator lacks proportional control and is permitted only under the following conditions: operating frequency ≤ 60 cycles per hour, single continuous operation duration ≤ 15 minutes, and operating duty cycle ≤ 33.3%.

The BD300-IIC intermittent modulating actuator features proportional control. Its applicable conditions are: operating frequency ≤ 60 cycles per hour (for three-phase models, the short-term operating frequency can reach up to 600 cycles per hour), continuous operation time ≤ 15 minutes, and duty cycle ≤ 33.3%.

Schematic diagram of BDBDM-IIC outline dimensions
Schematic diagram of BDBDM-IIC outline dimensions

Specifications

ParameterValue
Torque Range (Base Unit)50 – 3000 N.m
Torque Range (with W-Gearbox)Up to 54000 N.m
Speed Range (rpm)12, 24, 36, 48, 72, 96, 144 (depending on model)
Modulating Speed Recommendation12 rpm or 24 rpm for best precision.
Duty Cycle (BD-IIC)33.3% (max 15 min continuous run).
Duty Cycle (BDM-IIC)50% (1200 starts/hour max).
Control Signal Isolation1500Vac optical isolation between field I/O and logic.
LCD Resolution128 x 64 dot matrix with backlight.
Fieldbus RedundancyAvailable for Profibus-DP (PRV0, PRV1) and Modbus (MR).
Compliance StandardsGB/T3836.1/2/31-2021, GB4208-2017, ISO5210:2017.

Data sheet

BD300-IICThree Phase
Output Speed (rpm)Rated Torque (N.m)Motor Power (KW)Rated Current (A) Locked Rotor Current(A)
24300051582.73
36200051582.73
48150051582.73
72100051582.73
9675051582.73
14450051582.73